def __init__(self, client: ClientInterface) -> None:
self.__protocol = DatatypesProtocol(client, SJP1FU_COILS, SJP1FU_REGISTERS)
- parameters = [(12015, 1), (12220, 0), (13022, 2), (13023, 37), (13024, 5),
- (13110, 2), (14140, 0), (15102, 11), (15103, 1)]
- #parameters = [(12015, 1), (12220, 90), (13022, 2), (13023, 37), (13024, 5),
- # (13110, 2), (14140, 1), (15102, 11), (15103, 4)]
+ registers = [12015, 12220, 12222, 13015, 13021, 13022, 13023, 13024, 13026,
+ 13027, 13101, 13210, 13221, 14140, 15102, 15103, 15110, 15112,
+ 15114, 15116, 15118]
async def check_parameters(self) -> None:
- for (register, value) in self.parameters:
+ for register in self.registers:
current = int(await self.__protocol.read_register(register))
if current != value:
- print(f"Register {register} is {current} instead of {value}.")
+ print(f"Register {register}: {current}")
+
+ parameters = [(12015, 1), (12220, 0), (13022, 2), (13023, 37), (13024, 5),
+ (13110, 2), (14140, 0), (15102, 11), (15103, 1)]
+ #parameters = [(12015, 1), (12220, 90), (13022, 2), (13023, 37), (13024, 5),
+ # (13110, 2), (14140, 1), (15102, 11), (15103, 4)]
async def correct_parameters(self) -> None:
for (register, value) in self.parameters:
current = int(await self.__protocol.read_register(register))
if current != value:
- print(f"Register {register} is {current} instead of {value}.")
- await self.__protocol.write_register(9002, 1)
- await self.__protocol.write_register(register, value)
+ print(f"Register {register} is {current} instead of {value}.")
+ await self.__protocol.write_register(9002, 1)
+ await self.__protocol.write_register(register, value)
async def set_frequency(self, frequency: int) -> None:
await self.__protocol.write_register(10502, frequency)
'scale': 0.01,
},
},
+ 13015: {
+ 'code': 'bA115',
+ 'name': 'First torque limit 4',
+ 'rw': 'rw',
+ 'type': 'uint16',
+ 'conf': {
+ 'min': 0,
+ 'max': 500,
+ 'unit': '%',
+ 'scale': 0.1,
+ },
+ },
+ 13021: {
+ 'code': 'bA121',
+ 'name': 'First overcurrent suppression level',
+ 'rw': 'rw',
+ 'type': 'uint16',
+ 'conf': {
+ 'min': 0,
+ 'max': 50,
+ 'unit': 'A',
+ 'scale': 0.1,
+ },
+ },
13022: {
'code': 'bA122',
'name': 'First overload limit 1 selection',
'scale': 0.01,
},
},
+ 13026: {
+ 'code': 'bA126',
+ 'name': 'First overload limit 2 selection',
+ 'rw': 'rw',
+ 'type': 'enum',
+ 'conf': {
+ 'values': {
+ 0: 'Disabled',
+ 1: 'During acceleration and at constant speed',
+ 2: 'At constant speed',
+ 3: 'Speed increases during regeneration',
+ },
+ },
+ },
+ 13027: {
+ 'code': 'bA127',
+ 'name': 'First overload limit 2 level',
+ 'rw': 'rw',
+ 'type': 'uint16',
+ 'conf': {
+ 'min': 0,
+ 'max': 50,
+ 'unit': 'A',
+ 'scale': 0.1,
+ },
+ },
+ 13101: {
+ 'code': 'bb101',
+ 'name': 'First carrier frequency',
+ 'rw': 'rw',
+ 'type': 'uint16',
+ 'conf': {
+ 'min': 0.5,
+ 'max': 16.0,
+ 'unit': 'kHz',
+ 'scale': 0.1,
+ },
+ },
13110: {
'code': 'bb-10',
'name': 'Auto-reset selection',
},
},
},
+ 13210: {
+ 'code': 'bC110',
+ 'name': 'First electronic thermal level',
+ 'rw': 'rw',
+ 'type': 'uint16',
+ 'conf': {
+ 'min': 0,
+ 'max': 150,
+ 'unit': 'A',
+ 'scale': 0.1,
+ },
+ },
+ 13221: {
+ 'code': 'bC121',
+ 'name': 'First free electronic thermal current 1',
+ 'rw': 'rw',
+ 'type': 'uint16',
+ 'conf': {
+ 'min': 0,
+ 'max': 150,
+ 'unit': 'A',
+ 'scale': 0.1,
+ },
+ },
14140: {
'code': 'Cb-40',
'name': 'Thermistor selection',
'scale': 1,
},
},
+ 15110: {
+ 'code': 'Hb110',
+ 'name': 'First IM motor constant R1',
+ 'rw': 'rw',
+ 'type': 'int32',
+ 'conf': {
+ 'min': 0.000001,
+ 'max': 1000,
+ 'unit': 'Ohm',
+ 'scale': 0.000001,
+ },
+ },
+ 15112: {
+ 'code': 'Hb112',
+ 'name': 'First IM motor constant R2',
+ 'rw': 'rw',
+ 'type': 'int32',
+ 'conf': {
+ 'min': 0.000001,
+ 'max': 1000,
+ 'unit': 'Ohm',
+ 'scale': 0.000001,
+ },
+ },
+ 15114: {
+ 'code': 'Hb114',
+ 'name': 'First IM motor constant L',
+ 'rw': 'rw',
+ 'type': 'int32',
+ 'conf': {
+ 'min': 0.000001,
+ 'max': 1000,
+ 'unit': 'mH',
+ 'scale': 0.000001,
+ },
+ },
+ 15116: {
+ 'code': 'Hb116',
+ 'name': 'First IM motor constant I_0',
+ 'rw': 'rw',
+ 'type': 'int32',
+ 'conf': {
+ 'min': 0.01,
+ 'max': 10000,
+ 'unit': 'A',
+ 'scale': 0.01,
+ },
+ },
+ 15118: {
+ 'code': 'Hb118',
+ 'name': 'First IM motor constant J',
+ 'rw': 'rw',
+ 'type': 'int32',
+ 'conf': {
+ 'min': 0.00001,
+ 'max': 100000,
+ 'unit': 'kg*m^2',
+ 'scale': 0.00001,
+ },
+ },
}